Question #1 Topic 1

What are two valid cluster interconnect switches? (Choose two.)

  • A. NetApp CN610
  • B. Cisco Nexus 5596
  • C. Cisco Nexus 9504
  • D. Cisco Nexus 7004
Reveal Solution Hide Solution   Discussion  

Correct Answer: AB 🗳️
Reference -
https://library.netapp.com/ecm/ecm_get_file/ecmp1115327

Question #2 Topic 1

A Cisco UCS system is operating in FC End-Host Mode. The fabric Interconnects are uplinked into Nexus 5672UP switches using native FC. The service profiles are unable to boot from SAN using FC. When executing the show flogi database command on the Nexus switches, only the Fabric Interconnect port WWNs are visible. No service profile WWNs are shown.
What caused this issue?

  • A. The Nexus switches do not have NPV enabled.
  • B. The Nexus must be configured for FCoE instead of native Fibre Channel.
  • C. The Nexus switches do not have NPIV enabled.
  • D. The zoning on the Nexus switches is incorrect.
Reveal Solution Hide Solution   Discussion  

Correct Answer: C 🗳️
Reference -
https://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-manager/whitepaper_c11-697337.html

Question #3 Topic 1

Click the Exhibit button.

An administrator is building a FlexPod configuration with UCS 6296 Fabric Interconnect devices that support legacy Fibre Channel 9FC) connections. The administrator uses UCS Manager to configure the unified ports on the Fabric Interconnect.
Referring to the exhibit, how many ports will FC use after the configuration is completed?

  • A. 16
  • B. 2
  • C. 1
  • D. 6
Reveal Solution Hide Solution   Discussion  

Correct Answer: A 🗳️

Question #4 Topic 1

An administrator is configuring a Flexpod Datacenter solution. The UCS service profiles will use FCoE connectivity to the NetApp cluster.
Which pool is needed to configure the vHBA templates?

  • A. WWPN pool
  • B. MAC pool
  • C. IQN pool
  • D. WWNN pool
Reveal Solution Hide Solution   Discussion  

Correct Answer: A 🗳️